Centralized automatic fire alarm control system consists of centralized fire alarm controller(linkage-type), gas fire-extinguisher control panel, fire linkage control equipment, various fire detectors, manual fire alarm button, various modules, fire telephone for special use, power system, grounding system and connection cable. Even in the early stages of the fire, physical quantities like smoke, heat, flame and others caused by the combustion can be changed into electrical signals through the fire detector and transmitted to the fire alarm controller, which meanwhile will inform the entire floor in the form of sound or light for evacuation. And the controller will record the location and time of the fire for the people to detect the fire in time and take effective measures to extinguish the initial fire and minimize the loss of life and property caused by the fire.


--- 

Business Layer Supported

Automatic fire alarm technology provided by Winsion has the function to control and display status of fire equipment including on and off. Switching on/off the fire water pump, smoke prevention and smoke exhaust fan can be both automatically and manually controlled. It can display location of fire alarm and fault alarm, site map of important location of fire protective object, evacuation passage and location of fire equipment, and working status of system power supply. The fire control room will cut off the relevant parts of the non-fire power and connect to the alarm device and fire emergency lights and evacuation lights after confirm the fire. The fire control room will stop all elevators on the ground floor and received the feedback after confirm the fire. It ensures system network response time less than 3 seconds, loop response time less than 0.85 second, average non-fault time of system equipment MTBF>50000 hours, system equipment fault recovery time MTTR<30 minutes, designed system lifetime: overall service life of FAS system not less than 15 years. With high security, it can prevent unsafe factors due to internal causes of insecurity; It has lightning protection measures, good and reliable grounding, anti-over-voltage, anti-surge, anti-short circuit and other security measures.


Core Business Layer

The fire alarm has the highest priority. When the fire and other alarms exist at the same time, the alarm host will give priority to the fire alarm. The alarm host can automatically pop up the corresponding plane map of the alarm area. The pop-up time is no more than 1 second.


Application Layer

The system has the network self-diagnosis program that can judge the location and reason of the network fault through this self-diagnose program and carry on alarm in time. With friendly man-machine interface, we can understand the information of the equipment through the graphic window. And it can zoom in or our through the menu to the predetermined site plan to obtain detailed information. With a multi-level password, different levels of the operator has different access rights; through the history window can display simple and accurate required records. The data can be classified to be read and printed. Through the analysis of the event storage file to understand when and what happened to facilitate the analysis of the reasons for the incident; with a certain degree of redundancy measures to meet the specific state of affairs that still have a certain ability to operate; Adequate standard interface provided for link with other equipment.